AMV6 Basic

AMV6 All Inverter Multi VRF System adopts high-efficiency alternative control method to intelligently adjust the distributing method according to the demand of indoor load, which has ensured the service life of the integrated module, and improved the overall operating energy efficiency at the same time. Besides, new generation of intelligent management control solution and clean and healthy fresh air solution are attached as well, thus the unit is excellent in the aspects of energy conservation, comfort and stability.

  • Heating -30~ 24; Cooling -5~ 55
  • New type compressor: improved partial load efficiency
  • Efficient heat exchange: layered dual-zone heat exchange
  • New generation intelligent defrosting: self-adaptive capacity according to systemload,pressure and temperature
  • Self-balancingcontrol without oil balance pipe
  • The capacity is from 22.4kW to 246 kW.
  • The maximum length after the first branch pipe is 120m
1-1-amv6-224-335-top_asami_1663157216-843f05be945ca5f5997960a35b0d5aad.png
Features and benefits
0000_close-up-ventilation-system-1_9269-cec468156f677e86422669cfb655545f_1664181143-d908d9c4575af39dc8e6ef05b1becfb1.png
High-efficiency EVI control compressor
High-efficiency EVI control compressor

which is developed according to the features of VRF unit, its 0-420HZ adjusting range can perfectly match with the whole unit in stepless inverter operation, so as to excel the performance to the greatest extent.

0000_new-project_1662988551-d2a7a414f5d72161ca867240eca3d95a.jpg
The “Reverse-S shape”
The “Reverse-S shape”

tail design fan blade can effectively increase the working area of fan blades and greatly improve the air volume. The tail of the blade adopts the aircraft winglet design, which can effectively suppress the tip vortex caused by wing tip pressure difference and reduce noise.

0000_new-project_1664181794-5b97ccf240c661759671997f3fe1cec6.jpg
Dust Prevention Function
Dust Prevention Function

– According to operating time of unit and real-time operating parameters, situation of heat exchanger can be estimated. When the accumulative dust of heat exchanger impacts the heat exchange efficiency, activating the backward operating function of fan can effectively remove the dust.

0000_pexels-max-vakhtbovych-6316067_1664181232-fca225fba210f6168153a407edb38129.jpg
Lightning Prevention Function
Lightning Prevention Function

- Central air conditioning system has lightning protection and anti-surge function, which can effectively prevent the impact on air conditioning system due to instant overvoltage or overcurrent, so as to protect the personal and property safety of user.

0000_new-project_1664181879-ac68d2c28812f30508d2c3122fc2656e.jpg
Wind Prevention Function
Wind Prevention Function

– Before the unit is turned on, if the fan conducts backward operation due the adverse wind, it will adopt dynamic braking to stop the backward fan, and then turn on the unit according to normal program.

0000_new-project_1664181512-a6aad85dea649295903efe5a51d2772d.jpg
Snow Prevention Function
Snow Prevention Function

– In order to prevent the influence of snow accumulated on the top of the outdoor fan, the unit will automatically turn on the fan to clear the snow and ensure normal operation.